TY10镜面冷凝式露点湿度计ZX21

TY10

373镜面冷凝式露点湿度计

ZX21
373镜面冷凝式露点湿度计
订 货 号:ZY319933 品    牌:RH Systems 产    地:美国 市 场 价: 折 扣 价: 发货周期:现货或5天内
加入购物车 支付宝购买 询价留言
分享到:分享到搜狐微博 分享给QQ好友 分享到爱分享 分享到白社会 分享到开心网 分享到人人网 分享到豆瓣 分享仪器
产品描述技术方案相关仪器最新上架商品咨询使用评价
镜面冷凝式露点湿度计
 
The 373 Dew Point Mirror is a precision hygrometer exploiting advances in digital technology to satisfy the highest requirements in the measurement of humidity. As a true laboratory reference instrument, the 373 relies on proven optically detected chilled mirror techniques. This ensures a direct, accurate, and stable measurement of the actual humidity over a wide range of temperatures. The measured humidity may be displayed in a variety of parameters including Dew Point, Frost Point, %RH, PPMv, PPMw, Absolute and Specific Humidity. Choose your parameters. Choose your units. Choose your language. Its all user selectable from the front panel.
Head heating, and built in control for external heated hoses, allow for accurate measurement of above ambient dew points. And with the internal gas pump and electronic flowmeter, gas sampling requires the connection of only one external tube. The system is supplied as either a bench style instrument, or can be fitted with optional mounting hardware for a standard 19" rack.
General Information
Graphic Display
Full Color Hi-Resolution LCD Touch Screen -
User Selectable Display Parameters -
Parameters Selectable as Numeric or Graphic -
User Selectable Units -
The system uses an active matrix 640x480-pixel full color liquid crystal display with an integral touch panel. It has a high contrast ration and a wide viewing angle for easy readability. Data is displayed with large, easy to read characters. Using the on screen menus, you can configure the display for for a variety of humidity, temperature, and pressure parameters. The parameters can be viewed in either numeric or graphic (strip chart style) format. System units are user selectable and may be set to any combination of SI and non-SI units.
Digital Control
Digital Measurement and Control of Mirror Temperature - The reflected light from the mirror is continuously measured by a high resolution A/D converter to detect the dew/frost layer thickness. This digital signal is then used in the control algorithm to properly drive the peltier element, establishing and maintaining the dew thickness at the equilibrium point. The mirror temperature is measured by a 100-ohm platinum resistance thermometer which is connected directly to a high accuracy, high precision A/D converter. The resistance of the thermometer is measured by the A/D converter and used, along with calibration coefficients, to computer mirror temperature.
Dew/Frost Determination
Automatically Discriminates Between Dew and Frost - For mirror temperatures above 0ºC, water vapor condenses on the mirror as liquid water (dew). A condensation layer resulting from a mirror temperature above 0ºC is considered a dew point.
For mirror temperatures far below 0ºC, water vapor condenses on the mirror as solid ice (frost). A condensation layer resulting from a mirror temperature far below 0ºC is considered a frost point.
However, for mirror temperatures between 0 and approximately -20ºC, the state - water or ice - of condensed layer is indeterminate. In this temperature range, it is difficult to know, without visual observation, whether the mirror is controlling at the dew point or at the frost point. Since these two states occur at different temperatures for gas of the same water vapor content, it is important to determine which it is. The errors resulting from this problem can be in excess of ± 2ºC
To correct the situation, this system can be commanded to automatically force all sub-zero condensation to a known state of frost. This is accomplished by rapidly cooling the mirror to below -40ºC, then quickly returning it to the previously predicted frostpoint temperature. It is then allowed to stabilize while ensuring the mirror temperature remains below 0ºC. Once forced to frost in this manner, the condensation will remain in frost for all subsequent mirror temperatures that continue to remain below 0ºC.
Once the mirror temperature has risen above 0ºC, any further attempts to stabilize in the indeterminate range between 0 and -20ºC cause the system to once again cycle through forced frost formation. A forced frost cycle may also occur at the completion of any automatic or manual mirror check.
By ensuring that sub-zero mirror temperatures are always forced to frost, the mirror temperature can be taken as the frost point temperature. Since the dew point vapor pressure and the frost point vapor pressure are equal, dew point temperature can be mathematically computed.
ORIS
Optical Response Injection System - ORIS allows for faster measurements at low frost points, generally below about -60ºC. Typically, at these low frost point conditions, a chilled mirror hygrometer must cool the mirror to a value well below the actual frost point temperature in order to start the condensation process on the mirror. But due to the low water vapor content of the gas, it can take a very long time to establish a suitable frost layer on the mirror, then stabilize it at the proper equilibrium temperature. This can often take in excess of several hours. And the lower the frost point, the longer it takes.
ORIS solves this problem by momentarily injecting a small amount of water vapor into the gas stream to assist the initial formation of frost on the mirror, significantly reducing the amount of time required for a stable measurement. Measurements that once took several hours or more, can now be performed in a matter of minutes thanks to ORIS.
Programmable Outputs
2 Configurable 12-Bit Analog Outputs -
User Selectable Parameter and Range -
Communication Interface
Bi-directional RS-232 -
Obtain Readings -
Read/Store System Configuration Parameters -
Verify/Edit Calibration Coefficients -
Abbreviated Specifications
Dew/Frost Point Accuracy: 0.1°C
Dew/Frost Point Ranges Available -60°C to +20°C
(option-L)  -80 to 20°C
(option-LX)  -95 to 20°C
(option-H)  -30 to +70°C
(option-HX)  -20 to +100°C
Readout High Contrast Color Graphic LCD,
Numeric Digits 0.5" (1 cm) High
Power Requirements: (specify when ordering)
 115VAC 60Hz, or 230VAC 50Hz
 
购买提示  

镜面冷凝式露点湿度计

购买提示

1.阁下有任何产品问题请致电400-663-9117.
2.中仪将提供北京、上海、深圳、南京、重庆送货上门服务.
3.我们提供镜面冷凝式露点湿度计计量送检,在签收前请详细核查资料信息.
4.TY10镜面冷凝式露点湿度计价格根据配置和货期不同而不同,具体以合同为准.
5.我们为阁下提供保修TY10镜面冷凝式露点湿度计售后维修服务,提供后期技术支持.
6.阁下对TY10镜面冷凝式露点湿度计使用方法等有需求时,将为阁下找到镜面冷凝式露点湿度计说明书.
最近浏览

RH Systems373镜面冷凝式露点湿度计

代理商厂商品牌售后维修区域:北京-上海-浙江-广东-河南-杭州-郑州-广州-深圳-佛山-惠州-厦门-汕头-台湾-香港-天津-西安-宝鸡-杭州-温州-常州-无锡-苏州-南京-镇江-扬州-南通-合肥-徐州-常熟-石家庄-太原-呼和浩特-沈阳-长春-哈尔滨-南京-合肥-福州-南昌-济南-郑州-武汉-长沙-广州-南宁-海口-成都-贵阳-昆明-拉萨-西安-兰州-西宁-银川-乌鲁木齐-杭州-沈阳-长春-哈尔滨-济南-武汉-广州-南宁-成都-西安-大连-宁波-厦门-青岛-深圳-杭州-淮安-连云港-昆山-嘉兴-湖州-秦皇岛-邯郸-邢台-保定-张家口-承德-廊坊-呼和浩特-包头-鞍山-大庆-锦州-铁岭-盘锦-湛江-萧山-辽宁-淄博-宁夏-绵阳-云南-朝阳-陕西-青海-北海-唐山-吉林-苏州-昆山-无锡-镇江-常州-连云港-淮安-淮阴-盐城-扬州-徐州-宜兴-江阴-南通-扬州-上海-滁州-内蒙古-新疆有销售.北京亦庄开发区,天津滨海开发区,秦皇岛经济开发区,太原经济开发区,呼和浩特经济开发区,沈阳经济开发区,营口经济开发区,大连经济开发区,长春经济开发区,哈尔滨经济开发区,虹桥经济开发区,漕河泾开发区,连云港开发区,南通开发区,昆山开发区,南京开发区,杭州开发区,萧山开发区,温州开发区,宁波开发区,芜湖开发区,合肥开发区,福州开发区,福清融侨开发区,东山开发区,南昌开发区,威海开发区,烟台开发区,青岛开发区,郑州开发区,武汉开发区,长沙开发区,萝岗区开发区,广州南沙开发区,惠州大亚湾开发区,湛江开发区,南宁开发区,重庆开发区,成都开发区,贵阳开发区,昆明开发区,拉萨开发区,西安开发区,兰州开发区,西宁开发区,银川开发区,乌鲁木齐开发区,石河子开发区,金桥出口加工区,苏州工业园,宁波大榭开发区,厦门海沧投资区,海南洋浦开发区。

按字母分类: A| B| C| D| E| F| G| H| I| J| K| L| M| N| O| P| Q| R| S| T| U| V| W| X| Y| Z| 热门一| 热门二| 热门三| 热门四| 热门五|


中仪主页联系中仪了解中仪版权声明友情链接站点地图广告服务
CopyRight 2003年创立  版权所有  MRO工业品就是要仪器网
(5)
产品对比产品对比 隐藏对比框
对不起,您还没有选择产品
开始对比清 空