Warranty: |
1 Year |
|
Battery Life: |
200 hours(Alkaline) |
|
Size: |
WxHxD): 76 x 228 x 39 mm (3˝ x 9˝ x 1.5˝) |
|
Weight: |
(incl. Battery): 465 grams |
|
Safety: |
CAT II 600 V, CAT III 300 V |
|
DC Voltage Ranges: |
|
600 V |
|
DC Voltage Accuracy: |
|
± (0.75 % rdg + 2 dgts) |
|
DC Voltage Resolution: |
|
1 V in 600 V range |
|
DC Voltage Input Impedance: |
|
10 MΩ |
|
AC Voltage (40-450 Hz) Range: |
|
400 V, 600 V |
|
AC Voltage (40-450 Hz) Accuracy: |
|
± (1.2 % rdg + 5 dgts) |
|
AC Voltage (40-450 Hz) Resolution: |
|
0.1 V in 400 V range |
|
AC Voltage (40-450 Hz) Input Impedance: |
|
10 MΩ |
|
DC Current Ranges: |
|
400 A, 600 A |
|
DC Current Accuracy: |
|
± (2 % rdg + 5 dgts) |
|
DC Current Resolution: |
|
0.1 A in 400 A range |
|
AC Current (40-450 Hz): |
|
400 A, 600 A |
|
AC Current (40-450 Hz): |
|
± (2 % rdg + 5 dgts) |
|
AC Current (40-450 Hz): |
|
0.1 A in 400 A range |
|
Frequency (Hz), Current and Voltage Ranges: |
|
4 kHz, 20 kHz |
|
Frequency (Hz), Current and Voltage Accuracy: |
|
± (0.5 % rdg + 5 dgts) |
|
Frequency (Hz), Current and Voltage Resolution: |
|
1 Hz in 4 kHz range |
|
Frequency (Hz), Current and Voltage Sensitivity: |
|
5 A/1 V in 4 kHz range, 5 A/5 V in 20 kHz range |