Product Description
HBE-95 is a "state of the art" surface coating designed to solve specific industry problems by combining the unique features of epoxy and proprietary cure technologies.
HBE-95 is a 100% solids, two-component epoxy coating system which has been specifically designed as an exterior coating applied to bare steel for protection of pipe joint girth welds, valves and fittings, or as a touch-up material or rehabilitation system for mainline coatings.
Typical Uses
Protective coating for pipelines in buried or immersed applications. Used as a direct-to-metal corrosion and abrasion-resistant coating and as a rehab coating on steel pipelines and at girth welds. Also used as touch-up material for mainline coatings. Excellent coating for pipeline valves, fittings, and bends.
Features
High Build in a single coat.
Sets and cures over a broad temperature range
Environmentally safe.
100% solids, Zero V.O.C.
Excellent adhesion to grit blasted steel -- an ideal mainline corrosion coating for pipelines.
Superior adhesion to Fusion Bonded Epoxy (FBE) Coatings -- ideal coating for joint protection and repair of FBE coated pipe.
Excellent chemical & abrasion resistance.
Outstanding resistance to cathodic disbonding up to 95°C (203°F) operating temperature.
Easily applied with brush or roller.
About CANUSA-CPS
CANUSA-CPS-CPS is a leading manufacturer of specialty pipeline coatings which, for over 30 years, have been used for sealing and corrosion protection of pipeline joints and other substrates. CANUSA-CPS high performance products are manufactured to the highest quality standards and are available in a number of configurations to accommodate your specific project applications.
Technical Data
Coating Description
Epoxy
Conversion to Solids
100%
Theoretical Coverage
425 mil-sq. ft. / liter (1605 mil-sq. ft. / US gallon)
(1.0 mm-m2 / liter)
Typical Thickness
>20 mils
Flashpoint (T.C.C)
>95°C (203°F)
Mixing Ratio (by Volume)
3 Parts Base to 1 Part Hardener
Typical Product Properties
 
Coating
Property
Test
Standard
Unit
Typical
Values
Hardness
ASTM D2240
Shore D
> 85
Adhesion
     To Steel (Sp10 at 24 mils)
     To FBE
   
ASTM D4541
ASTM D4541
   
psi
psi
   
> 2000
> 2000
Cathodic Disbondment
     28 days @ 23°C
     28 days @ 80°C
     28 days @ 95°C
   
CSA Z245.20
CSA Z245.20
CSA Z245.20
   
mm, radius
mm, radius
mm, radius
   
< 3
< 8
< 8
Impact Resistance
     at -30°C
     at 25°C
  
CSA Z245.20
CSA Z245.20
   
Joules (in-lb)
Joules (in-lb)
   
> 3.0 (> 26.5)
> 3.0 (> 26.5)
Hot Water Immersion
     28 days at 75°C
     28 days at 95°C
  
CSA Z245.20
CSA Z245.20
   
1 to 5
1 to 5
   
1, excellent
1, excellent
Flexibility
ASTM D570
deg / pipe diam.
> 0.7
Water Absorption
ASTM D149
%
< 0.1
Dielectric Strength
ASTM D543
Volts / micron
(Volts / mil)
> 16
(> 400)
Chemical Resistance
ASTM D543
various solutions
excellent
Surface Preparation
Direct-to-steel
Remove all visible deposits of oil, grease and other contaminates by solvent washing in accordance with SSPC-SP1. Abrasive blast surfaces to a Near-White (SSPC-SP 10, NACE 2, SA2 1/2) or better, with a 2-4 mil blast profile.  
On cured pipe coating
Remove gloss on surface by light abrasive blasting or power tool. All surfaces to be coated must be completely dry, free of moisture, soil, dust and grit at the time the coating is applied. All weld splatter must be removed from the surface and rough welds must be ground smooth prior to coating.
Cleanup, Storage & Safety
Clean-up
For clean-up use xylene, MEK or mixture. 
Storage
Products must be shipped and stored at temperatures between 15°C (60°F) and 40°C (105°F). DO NOT FREEZE.
Safety
Material Safety Data Sheet and product labels contain detailed health, hygiene and safety information. This coating is intended for industrial use by properly trained professional applicators. Do not apply without adequate air exchange and ventilation in enclosed areas. Use fresh air respirator in confined areas. Wear protective clothing when spraying the coating. Breathing fumes or contact with skin can cause respiratory and other allergic reactions in some people. See MSDS for HBE-95-BG Base and MSDS for HBE-95-BG Cure.
Mixing & Application Instructions
For detailed application instructions please refer to HBE-95 Installation Guide.
Materials must be allowed to warm to at least 28°C (70°F) prior to mixing.
Pre-mix Base (more viscous component) slowly with a variable speed drill gun fitted with an appropriate mixing impeller.
Pour pre-measured Hardener into pre-measured Base.
At temperatures between 15°C (59°F) and 40°C (105°F). Mix for one (1) minute blend both parts to create one uniform color with no streaks. Begin mixing slowly. Caution: Mix at a speed that ensures a uniform mix, but does not create a vortex in the liquid. Slow mixer down at surface of the liquid to prevent introduction of air into the coating.
Pot-life is approximately 15 minutes at 20°C (70°F) and shortens with increased temperatures.
HBE-95 must be applied to clean dry surface only.
Ambient conditions for successful application include: relative humidity less than 85%; and the substrate temperature greater than 3°C (5°F) above the dew point.
The acceptable substrate temperature range for application of HBE-95 is 10°C (50°F) to 100°C (212°F). Applying onto warm substrate greater than 38°C (100°F) enhances coating adhesion.
Formulated to mixing ratio of 3 parts Base to 1 part Hardener by volume.
If additional coats are required, they shall be applied while the preceding coat is still tacky (no tie coat needed). The maximum over-coating interval shall not exceed two (2) hours at 25°C (77°F) without roughening the surface. If recoating interval has been exceeded, surface must be blast roughened prior to application of topcoat.
A minimum of four (4) hours curing above 20°C (68°F) is required prior to handling. Handling time maybe longer at lower temperatures.
Apply thoroughly mixed HBE-95 by brush, roller or trowel. When coating pipe, remove application tools on the upstroke to prevent pulling material down and off the pipe bottom.
How to Order
Product Designation
Package Contents
HBE-95-BG Kit-0.5
HBE-95-BG Kit-1.0
HBE-95-BG Kit-1.5
HBE-95-BG Application Kit
375 mL of HBE-95 Base, 125 mL of HBE-95-BG Hardener.
750 mL of HBE-95 Base, 250 mL of HBE-95-BG Hardener.
1125 mL of HBE-95 Base, 375 mL of HBE-95-BG Hardener.
1 pair of rubber gloves, mixing sticks, application scraper.
 
购买提示  

HBE-95环氧树脂涂料

购买提示

1.阁下有任何产品问题请致电400-663-9117.
2.中仪将提供北京、上海、深圳、南京、重庆送货上门服务.
3.我们提供HBE-95环氧树脂涂料计量送检,在签收前请详细核查资料信息.
4.TY10HBE-95环氧树脂涂料价格根据配置和货期不同而不同,具体以合同为准.
5.我们为阁下提供保修TY10HBE-95环氧树脂涂料售后维修服务,提供后期技术支持.
6.阁下对TY10HBE-95环氧树脂涂料使用方法等有需求时,将为阁下找到HBE-95环氧树脂涂料说明书.
最近浏览

英国密析尔MICHELLHBE-95环氧树脂涂料

代理商厂商品牌售后维修区域:北京-上海-浙江-广东-河南-杭州-郑州-广州-深圳-佛山-惠州-厦门-汕头-台湾-香港-天津-西安-宝鸡-杭州-温州-常州-无锡-苏州-南京-镇江-扬州-南通-合肥-徐州-常熟-石家庄-太原-呼和浩特-沈阳-长春-哈尔滨-南京-合肥-福州-南昌-济南-郑州-武汉-长沙-广州-南宁-海口-成都-贵阳-昆明-拉萨-西安-兰州-西宁-银川-乌鲁木齐-杭州-沈阳-长春-哈尔滨-济南-武汉-广州-南宁-成都-西安-大连-宁波-厦门-青岛-深圳-杭州-淮安-连云港-昆山-嘉兴-湖州-秦皇岛-邯郸-邢台-保定-张家口-承德-廊坊-呼和浩特-包头-鞍山-大庆-锦州-铁岭-盘锦-湛江-萧山-辽宁-淄博-宁夏-绵阳-云南-朝阳-陕西-青海-北海-唐山-吉林-苏州-昆山-无锡-镇江-常州-连云港-淮安-淮阴-盐城-扬州-徐州-宜兴-江阴-南通-扬州-上海-滁州-内蒙古-新疆有销售.北京亦庄开发区,天津滨海开发区,秦皇岛经济开发区,太原经济开发区,呼和浩特经济开发区,沈阳经济开发区,营口经济开发区,大连经济开发区,长春经济开发区,哈尔滨经济开发区,虹桥经济开发区,漕河泾开发区,连云港开发区,南通开发区,昆山开发区,南京开发区,杭州开发区,萧山开发区,温州开发区,宁波开发区,芜湖开发区,合肥开发区,福州开发区,福清融侨开发区,东山开发区,南昌开发区,威海开发区,烟台开发区,青岛开发区,郑州开发区,武汉开发区,长沙开发区,萝岗区开发区,广州南沙开发区,惠州大亚湾开发区,湛江开发区,南宁开发区,重庆开发区,成都开发区,贵阳开发区,昆明开发区,拉萨开发区,西安开发区,兰州开发区,西宁开发区,银川开发区,乌鲁木齐开发区,石河子开发区,金桥出口加工区,苏州工业园,宁波大榭开发区,厦门海沧投资区,海南洋浦开发区。

按字母分类: A| B| C| D| E| F| G| H| I| J| K| L| M| N| O| P| Q| R| S| T| U| V| W| X| Y| Z| 热门一| 热门二| 热门三| 热门四| 热门五|


中仪主页联系中仪了解中仪版权声明友情链接站点地图广告服务
CopyRight 2003年创立  版权所有  MRO工业品就是要仪器网
(5)
产品对比产品对比 隐藏对比框
对不起,您还没有选择产品
开始对比清 空