Battery diagnostic systems (BDS) continuously monitor all critical battery parameters, verify the integrity of the connected battery system, and alarm on any out-of-tolerance condition. Testing includes proactive, internal DC cell resistance measurements at programmed intervals recommended by IEEE standards. By tracking increases in internal cell resistance, the BDS predicts if the battery system will perform during a power outage.

The BDS-256XL Battery Diagnostic System

The BDS-256XL is a modular system that can monitor virtually any UPS battery configuration. The BDS-256XL consists of a Controller, Data Collection Module, and Resistance Test Module.
Interface to the BDS-256XL is done using the Alber Battery Monitor Data Manager (BMDM) software. The Battery Monitor Report Generator program creates reports from collected data.
The CM-XL8 Controller
The Controller, the brain of the system, coordinates alarms and traffic to and from the other system components. It can monitor up to eight strings of 256 cells on independent UPSs, for a total of 2048 cells per Controller. Its nonvolatile memory can hold up to a years worth of data. The built-in power supply provides 24VAC for all components in the system.
The DCM-XL48 Data Collection Module
The Data Collection Module (DCM) is a scanning voltmeter that acquires overall voltage, cell voltage, current, and temperature readings from the monitored battery string. The DCM can monitor cells or blocks from 1V to 16VDC. The DCM compares captured data with preset thresholds and alerts the user if any parameters are in violation. Each DCM can measure up to 48 cells or battery blocks per string. DCMs can be connected in series to monitor up to 256 cells per string. The DCM also controls the load module during a resistance test.
The RTM-XLR Resistance Test Module
The Resistance Test Module (RTM) provides the load during the patented resistance test. Without this component, the monitor system could not provide the high reliability and repeatable results that Alber customers rely on.

The BDS-256 System Features

•  Monitor up to 256 cells/modules per string. 2V cells, NiCd cells, 4V, 6V, 8V and 12V modules are supported.

•  Overall voltage, cell/module voltages, current, and temperature are continuously scanned and compared with programmed alarm levels.

•  Internal DC resistance tests are performed and compared to programmed alarm levels. All data is saved.

•  Overall voltage, cell/module voltages, current, and temperature readings are saved.

•  Discharges are detected and data saved. All parameters are scanned every four seconds during a discharge.

•  Discharges can be viewed in real time locally or remotely during the discharge event or later replayed in real or accelerated time.

•  Alarm events trigger an indicator, dedicated contact closure, programmed contact closure, and dial-out notification. All battery parameters can be set to page, fax, print, and/or sound an alarm.
•  Communication via network, modem, serial or USB. Optional TCP/IP interface for network or Internet communication. Industry standard MODBUS protocol interfaces to third party, building management systems.
•  No on-site computer required.
•  Modular design easily expands to monitor an unlimited number of strings. When used with the MPM-100, virtually all battery configurations can be managed with one software package.

•  Digital input/output option permits monitoring up to 16 inputs and up to 8 user-programmed outputs.

•  Monitor Load Control option enables the monitor system to control an Alber Continuous Load Unit (CLU) for performing battery capacity testing.

•  Automatically poll and retrieve data.

•  Reports can be e-mailed and then viewed using the free downloadable Alber Archive Reader.

•  Faulty cells detected during an unplanned discharge event can be reported in real time.
 
购买提示  

BDS-256XL电池诊断系统

购买提示

1.阁下有任何产品问题请致电400-663-9117.
2.中仪将提供北京、上海、深圳、南京、重庆送货上门服务.
3.我们提供BDS-256XL电池诊断系统计量送检,在签收前请详细核查资料信息.
4.TY10BDS-256XL电池诊断系统价格根据配置和货期不同而不同,具体以合同为准.
5.我们为阁下提供保修TY10BDS-256XL电池诊断系统售后维修服务,提供后期技术支持.
6.阁下对TY10BDS-256XL电池诊断系统使用方法等有需求时,将为阁下找到BDS-256XL电池诊断系统说明书.
最近浏览

阿尔伯BDS-256XL电池诊断系统

代理商厂商品牌售后维修区域:北京-上海-浙江-广东-河南-杭州-郑州-广州-深圳-佛山-惠州-厦门-汕头-台湾-香港-天津-西安-宝鸡-杭州-温州-常州-无锡-苏州-南京-镇江-扬州-南通-合肥-徐州-常熟-石家庄-太原-呼和浩特-沈阳-长春-哈尔滨-南京-合肥-福州-南昌-济南-郑州-武汉-长沙-广州-南宁-海口-成都-贵阳-昆明-拉萨-西安-兰州-西宁-银川-乌鲁木齐-杭州-沈阳-长春-哈尔滨-济南-武汉-广州-南宁-成都-西安-大连-宁波-厦门-青岛-深圳-杭州-淮安-连云港-昆山-嘉兴-湖州-秦皇岛-邯郸-邢台-保定-张家口-承德-廊坊-呼和浩特-包头-鞍山-大庆-锦州-铁岭-盘锦-湛江-萧山-辽宁-淄博-宁夏-绵阳-云南-朝阳-陕西-青海-北海-唐山-吉林-苏州-昆山-无锡-镇江-常州-连云港-淮安-淮阴-盐城-扬州-徐州-宜兴-江阴-南通-扬州-上海-滁州-内蒙古-新疆有销售.北京亦庄开发区,天津滨海开发区,秦皇岛经济开发区,太原经济开发区,呼和浩特经济开发区,沈阳经济开发区,营口经济开发区,大连经济开发区,长春经济开发区,哈尔滨经济开发区,虹桥经济开发区,漕河泾开发区,连云港开发区,南通开发区,昆山开发区,南京开发区,杭州开发区,萧山开发区,温州开发区,宁波开发区,芜湖开发区,合肥开发区,福州开发区,福清融侨开发区,东山开发区,南昌开发区,威海开发区,烟台开发区,青岛开发区,郑州开发区,武汉开发区,长沙开发区,萝岗区开发区,广州南沙开发区,惠州大亚湾开发区,湛江开发区,南宁开发区,重庆开发区,成都开发区,贵阳开发区,昆明开发区,拉萨开发区,西安开发区,兰州开发区,西宁开发区,银川开发区,乌鲁木齐开发区,石河子开发区,金桥出口加工区,苏州工业园,宁波大榭开发区,厦门海沧投资区,海南洋浦开发区。

按字母分类: A| B| C| D| E| F| G| H| I| J| K| L| M| N| O| P| Q| R| S| T| U| V| W| X| Y| Z| 热门一| 热门二| 热门三| 热门四| 热门五|


中仪主页联系中仪了解中仪版权声明友情链接站点地图广告服务
CopyRight 2003年创立  版权所有  MRO工业品就是要仪器网
(5)
产品对比产品对比 隐藏对比框
对不起,您还没有选择产品
开始对比清 空