Measures the rate of corrosion and other parameters of rebars.
The Gecor 6™ utilizes the polarization resistance technique to establish the corrosion rate.
This is a quantitative measure of the amount of steel oxidizing at the time of measurement. Up to 100 readings can be stored in memory for later uploading to a Personal Computer. Relative humidity, temperature, half-cell potentials and concrete resistivity also can be measured. Weighing only nine pounds, the system is easy to use, portable and menu driven.