Range |
0-2 ppm |
Accuracy |
+/- 10% of value |
Resolution |
0.01 ppm |
Response time |
10 seconds |
Sensor Type |
Electrochemical |
Display |
LCD |
Alarm |
Three relay options: SPST, 5 A @ 230 VAC resistive |
Outputs |
4 to 20mA, Relays. |
Temperature range |
-22 to 140F (-30 to +60 C) |
Power requirements |
12-30 VDC, 25 mA maximum in loop-powered mode |
Weight |
1 lb (.5 Kg) |
Supporting documents |
User manual and NIST Traceable Calibration Sheet included |
Warranty |
1 yr |
Electronic |
Repeatability: +/-1% |
Electronic Linearity |
+/-0.5% |
Zero Drift |
Less than 2% full scale per month, non-cumulative |
Span Drift |
Dependent on operating environment but generally less than 3% per month |
Serial Interface |
12-30 VDC, 200 mA maximum in 3-wire mode |
115 of 230 VAC, 50/60 Hz | |
Heated Sensor Power |
24 VDC connection, 250 mA max |
Relay Coil |
Programmable either normally energized or normally de-energized |
Enclosure |
Nema 4x poly carbonate |
Controls |
4 program switches on front transmitter |