Low Concentration Ozone |
0.000 to 0.500 ppm |
High Concentration Ozone |
0.20 to 10.00 ppm |
Accuracy |
|
Low concentration Ozone Head |
± 0.010 ppm (0 to 0.100 ppm) |
High concentration Ozone Head |
± 10% (0.20 to 10.00 ppm) |
T90 response time (standard) |
|
Low concentration Ozone Head |
60 seconds |
High concentration Ozone Head |
35 seconds |
Sensor type |
Gas-sensitive semiconductor |
Indicators |
Low, high, within control band, diagnostics |
Alarms |
2 alarms (Low Alarm & High Alarm) or Control |
Outputs |
Volt free (150mA max, 24v max, resistive) |
Temperature range |
23°F to 122°F (-5°C to 50°C) (sensor head and base unit) |
Humidity range |
5 to 95% (sensor head and base unit) |
Power requirements |
User supplied. 24v DC (18v - 26v DC), 500mA |
Size |
180mmL x 110 mmW x 90mmD (enclosure only) 230mmL x 110mmW x 90mmD (including nozzles) |
Weight |
30 oz |
Supporting documents |
User manual and NIST Traceable Calibration Sheet included |
Warranty |
1 yr |
I/O connectors (power, control signal) |
Eight pole M12 female panel mount connector and eight pole male cord connector |
Setting control and alarms |
16 position rotary switches |
Removable / replaceable sensor head |
Yes |
Enclosure rating |
IP41 & NEMA 2 equivalent |
Enclosure size |
180W x 110H x 90D (mm); 7 1/8 W x 4ľH x 3˝D (in) |
Enclosure casing |
Fiber reinforced plastic |