Preliminary Specifications Pressure range: |
Differential, +/- 1psi |
|
Pressure Non-Linearity: |
±0.25% FS |
|
Pressure Hysteresis |
+/- 0.05% FS |
|
Overpressure |
5x of pressure range |
|
OperatingTemperature: |
–40 to 125oC |
|
Thermal Hysteresis |
±0.1% FS |
|
Cable temperature |
-40 to 85oC with high temp option to 125oC |
|
Signal conditioner temperature: |
-40 to 85oC model DP_Industrial
–40 to 125oC (260 oF); model DP-HT |
|
Supply Current |
Less than10 ma total (transducer + electronics) |
|
Supply Voltage |
5.0 to 24.0 volt dc |
|
Sensor output: |
Options: 0-5volt, 4-20ma, PWM |
|
Guaranteed service life time |
5 Million cycles, 2 years. |
|
Frequency response: |
0.01 Hz to 500 Hz |
|
Signal to Noise Ratio |
2000:1 @ 10 Hz |
|
Pressure port |
½ inch NPT internal |
|
Response Time: |
50 ms (water) |
|
Case: |
NEMA-4/IP6 |